Solar Output Calculator

Estimate daily, monthly, and annual solar energy output. Calculates photovoltaic system output based on panel specifications, peak sun hours, system…

Calculates photovoltaic system output based on panel specifications, peak sun hours, system efficiency, and tilt/orientation factors. Accounts for inverter losses, soiling, and azimuth offset.

How is Solar Output Estimated?

Solar energy output depends on three key factors: panel capacity (kW), solar irradiance at the location (peak sun hours, PSH), and system efficiency (accounting for inverter, wiring, soiling, temperature, and shading losses).

Peak Sun Hours (PSH) represents the equivalent hours of full 1000 W/m² sunlight per day. A location receiving 1800 kWh/m²/year has 4.93 PSH daily average. PSH varies from 2-3 in northern Europe to 6-7 in desert regions. Tilt angle optimization (typically equal to latitude) can increase annual yield by 10-25%.

Real-world system efficiency is typically 75-85% of nameplate capacity due to: inverter losses (3-5%), DC wiring losses (2-3%), soiling (2-5%), temperature derating (5-15% in hot climates, panels lose ~0.4%/°C above 25°C), shading (0-15%), and degradation (0.5-0.8% per year).

Azimuth offset (deviation from true south in the northern hemisphere, true north in the southern) reduces annual output. The model integrates Liu-Jordan isotropic transposition over the year, so the derate follows the geometry rather than a fixed factor: at tilt = latitude, expect roughly 4% loss at a 45° offset, 16% at 90° (east/west), and about 45% facing due north. A flat (0°) array keeps about 88%. Bifacial panels can partially offset orientation losses by capturing reflected light on the rear side.

Formula: Daily Output = System Size (kW) × PSH × System Efficiency × Tilt/Azimuth Factor Monthly Output = Daily × 30 Annual Output = Daily × 365 Capacity Factor = Annual Output / (Size × 8760)

Example Calculation

10 panels × 400W = 4.0 kW system, PSH = 4.5, system efficiency 80%. Daily = 4.0 × 4.5 × 0.80 = 14.4 kWh. Monthly = 432 kWh. Annual = 5,256 kWh. Capacity factor = 5256/(4.0×8760) = 15.0%.

When to Use This Calculator

Common Mistakes to Avoid

How to Interpret Results

Related Standards & References

Frequently Asked Questions

What is the optimal tilt angle for solar panels?

As a rule of thumb, set tilt equal to latitude for maximum annual yield. Steeper tilt (latitude + 15°) favors winter generation, shallower (latitude - 15°) favors summer. For grid-connected systems maximizing annual output, latitude angle is optimal. Flat roofs often use 10-15° tilt for self-cleaning and wind load reduction.

How much roof space do I need for solar?

Modern 400W panels are approximately 1.7m × 1.0m (1.7 m²). For a 4 kW system (10 panels): ~17 m² of unshaded, south-facing roof. In practice, add 20-30% for spacing, setbacks, and obstructions. Flat roofs need more space due to tilt rack row spacing.